Sight Flow Indicators Window Type |
Sight Flow Indicators (Window Type)
Sight Flow Indicators are Suitable for transparent/ slightly opaque solution & gases window type sight flow indicator is suitable for safe indicator of liquid/ gases under vacuum temp & press also.
|
|
|
|
|
Flame Arresters |
Flame Arrester are safety devices used to prevent external fire entering in to the tank or inside the pipe line & ducts & to prevent flame spreading from in to or out of plant & equipments flame arresters are normally installed on the end of the line or above the vessel, where hazardous gases are normally vented out. The internal element or flame bank is made of metal sheet, the gas is allowed to pass along with the element which prevent fire entering in process on the event of external fire sizing / designing can be done with reference to API - 2000. Flame bank is so designed that the pressure drop is negligible . In any process or plant which us flammable gas, or vapour that could conceivably ignite flame, flame arresters must be used. To assist yours requirement the details such as the fluid, gas & vapour contains & tank size, apacity in ltr. pumping rates in & out from storage tank be specified, where the flame arresters are required.
|
|
|
|
|
Breather Valves |
Industrial Breather Valves
The breather valves are extensively used for automatic venting and for conservation of losses due to evaporation.Breather valves minimizes the risk of fire,explosion and collapsing of tank by relieving automatically the dangerous pressure and vaccum in the tank due to any reason.
|
|
|
|
|
Strainers |
Strainers is safety devices used to prevent external fire entering in to the tank or inside the pipe line & ducts & to prevent flame spreading from in to or out of plant & equipments flame arresters are normally installed on the end of the line or above the vessel, where hazardous gases are normally vented out. The internal element or flame bank is made of metal sheet, the gas is allowed to pass along with the element which prevent fire entering in process on the event of external fire sizing / designing can be done with reference to API - 2000. Flame bank is so designed that the pressure drop is negligible . In any process or plant which us flammable gas, or vapour that could conceivably ignite flame, flame arresters must be used. To assist yours requirement the details such as the fluid, gas & vapour contains & tank size, apacity in ltr. pumping rates in & out from storage tank be specified, where the flame arresters are required.
|
|
|
|
|
Orifice Plates And Flanges Assemblies |
Orifice Flange Assemblies are supplied ready to install in pipelines complete with Studs, Nuts, Jack Bolts, Gaskets and Drain Plugs. Orifice Flanges are manufactured in broad variety of materials to ASTM Standards viz.
|
|
|
|
|
Macleod Gauge |
Suitable for measurement of pressures in the range of 10 mm to 10² mm or 10³ mm of Hg. This convenient gauge is a modification of Macleod Gauge. This gauge eliminates the use of a movable reservoir of mercury, and also requires only about 12 cc of mercury for filling. The total size of this gauge is about 9”x6”.
|
|
|
|
|
|
|
|
|